NGT/RSW 92-1890

Type Output,kW Dimensions,w/h/d Weight, kg. Pressure drop flue gas side,mbar 
RSW 92 92 760/866/1046 260 0,5
RSW 107 107 760/856/1046 260 0,7
RSW 152 152 810/911/1296 350 1,2
RSW 190 190 810/911/1296 350 1,2
RSW 240 240 810/911 /1516 440 2,3
RSW 300 300 950/1031/1546 480 3,3
RSW 350 350 950/1031/1816 550 4,4
RSW 399 399 950/1031/1817 590 4,4
RSW 525 525 1060/1181/1838  860 3,3
RSW 600 600 1060/1181/2098 970 4,3
RSW 720 720 1260/1331/2158 1250 4,8
RSW 820 820 1260/1331/2158 1250 4,5
RSW 940 940 1260/1331/2398 1420 5,6
RSW 1060 1060 1450/1511/2420 1580 5,4
RSW 1250 1250 1450/1511/2420 2250 6,0
  RSW 1480 1480 1530/1661/2722 2650 6,5
  RSW 1600 1600 1530/1661/2722 2700 6,8
  RSW 1890 1890 1530/1661/2722 2850 7,0
  • Boiler body made entirely from steel, completely lined with an 80 mm layer of high density glass wool, in turn covered by a strong layer of tearproof material.
  • Maximum operating pressure 6 bars, higher pressures upon request.
  • Pressurised combustion chamber, completely cooled and protected by a system ensuring uniform division of the cold system return water, to avoid dangerous temperature differences. The burner is not aligned with the combustion chamber but rather has been moved downwards. This assists flame reversal, reduces the flue gas pressure drop and consequently extends the hot water generator’s range of application.
  • Tube bundle placed above the furnace so as to guarantee the flue gas passes through a hot section of the hot water generator and consequently reduce the possibility of condensate forming.
  • Turbulators featuring a new design able to increase heat exchange, without affecting pressure drop in the boiler.
  • Front door with reversible opening(right and left) and innovative closing system with micrometric adjustment on the hot water generator front plate. Up to model 940 the door is insulated with double lining, made up of one layer of fibre and one layer of Carbowool, while higher output models use a double layer of refractory concrete and insulation.
  • Threaded central heating flow outlet and return inlet connections up to model 399 and flanged PN10 for the remaining models.
  • Supplied in 3 parts: steel body, casing and satellite controls (satellite to be ordered separately).

CERTIFICATION

  • CE mark in accordance with the following directives
  • Gas Appliances (2009/142 EEC)
  • Efficiency (92/42 EEC)
  • Low Voltage (2006/95 EEC)
  • Electromagnetic Compatibility (2004/108 EEC)
rsw-gb-1.pdf
811.04 KB
Download
st_-_ngt_serie_quadra_11.pdf
92.5 KB
Download

Make request

Product image

NGT/RSW 92-1890