SANITARY WATER HEAT PUMPS “FERROLI”

Aqua1 Plus

90 HT

160 HT

200 HT

260 HT

200 LT

260 LT

 

Heating capacity (ISO)

W

1005

1600

1600

1600

1820

1820

 

Total power input in heating (ISO)

W

210

370

370

370

430

430

 

COP (ISO)

W/W

4,79

4,32

4,32

4,32

4,23

4,23

 

Rated current input in heating (ISO)

A

0,95

1,70

1,70

1,70

2,00

2,00

 

Max power input

W

270

500

500

500

530

530

 

Max current input

A

1,20

2,30

2,30

2,30

2,43

2,43

 

Warming up time (EN) (1)

h:min

5:30

6:41

7:16

9:44

8:17

10:14

 

Warming energy (EN) (1)

kWh

1,20

2,68

2,83

3,74

3,25

3,99

Heat pump

Stand-by input (EN) (1)

W

14

29

27,3

31

29

29

 

Class of usage (EN) (1)

Type

M

L

L

XL

L

XL

 

Power consumption during cycle of use WEL-TC (EN) (2)

kWh

2,20

4,43

4,18

6,17

3,97

6,19

 

COP DHW и (1)

W/W

2,70

2,63

2,80

3,10

2,94

3,08

 

Reference temperature (EN) (1)

°C

50,8

55,9

51,4

53,7

53,7

52,7

 

Max. quantity of water usable (EN) (2)

m3

0,094

0,233

0,260

0,358

0,275

0,342

 

Heating efficiency. Ref St. (EU)

%

104

104

110

121

117

121

 

Energy efficiency. Ref St. (EU)

A

A

A

A

A

A

 

Annual power consumption (EU)

kWh/year

489

986

929

1384

879

1393

Electric heating

Capacity

W

1200

1500

1500

1500

1500

1500

Input current

A

5,2

6,5

6,5

6,5

6,5

6,5

 

Total power input

W

1410

1870

1870

1870

1960

1960

Heat pump + electric heating

Total current

A

6,15

8,20

8,20

8,20

8,5

8,5

Max total power input

W

1470

2000

2000

2000

2030

2030

 

Max current

A

6,40

8,80

8,80

8,80

8,93

8,93

 

Volume

l

87

158

199

255

196

248

 

Max. operating pressure

MPa

0,7

0,7

0,7

0,7

0,7

0,7

Tank

Material

Type

Enamelled steel

 

Protection

Type

Magnesium anode

 

Isolation typethickness

Type/mm

Polyurethane / 50

 

Fan type

Type

Centrifugal

Air circuit

Air flow

m3/h

130

350 – 500

350 – 500

350 – 500

350-500

350-500

Pipe outlet diameter

mm

125

160

160

160

160

160

 

Max available pressure

Pa

120

200

200

200

200

200

 

Compressor

Type

Rotary

Refrigerant circuit

Refrigerant

Type

R134a

Evaporator

Type

Finned copper / aluminum battery

 

Condenser

Type

Aluminum tube wrapped externally to the tank

 

Material

Type

Enamelled steel

Solar coil

Total surface (ISO)

m2

0,6

1,0

 

Max. pressure (ISO)

Mpa

0,7

0,7

Sound power level

dB(A)

60

59

59

59

60

60

Weight

Net

kg

48,5

70

80

100

99

115,2

 

 

NOTE (ISO): data according to the standard ISO 255-3

(EN): data according to the standard EN 16147:2011

(EU): data according to the standard EU 812/2013

(1)   : heating cycle: Ambient temperature = 15 ° C B.S./12 ° C B.U. –

Initial water temperature = 10 ° C

(2)   : use temperature 40° C -inlet water tempeiature 10° C

  • Air-water heat pumps for domestic hot water preparation.
  • Storage in enamelled steel and externally wrapped condenser for the highest safety and hygiene.
  •  Max setpoint temperature 56°C from renewable energy.
  • Digital programmable electronics.
  • Heating settable integration with solar (model LT) or electric heating element (up to 70°C).
  •  Power settable integration with solar PV system.

Make request

Product image

SANITARY WATER HEAT PUMPS “FERROLI”

[contact-form-7 id="157" title="Make Product Request En"]